# How to configure Unitech devices with OEMConfig

OEMConfig is a new Android standard that allows device manufacturers (OEMs) to create custom enterprise features for their devices. Unitech OEMConfig (com.unitech.oemconfig) is the OEMConfig application developed by Unitech. It allows enterprises to configure and manage Unitech devices with its native management features. Hexnode provides a handy and intuitive interface where administrators can easily view and set up these Unitech-specific configurable items for devices.

 Notes: 
Works on Unitech devices running Android (6.0+) enrolled in the [Android Enterprise](https://www.hexnode.com/mobile-device-management/help/how-to-enroll-organization-in-android-enterprise-using-hexnode-mdm/) program.

 

Configure Unitech devices with Unitech OEMConfig
------------------------------------------------

Before configuring Unitech devices, make sure to:

- Enroll your organization in the Android Enterprise program.
- Enroll your devices in Android Enterprise ([Device Owner](https://www.hexnode.com/mobile-device-management/help/how-to-enroll-a-device-in-android-in-the-enterprise-as-device-owner-using-hexnode-mdm/) or [Profile Owner](https://www.hexnode.com/mobile-device-management/help/how-to-enroll-a-device-in-android-in-the-enterprise-as-profile-owner-using-hexnode-mdm/)).

Configuring devices with the Unitech OEMConfig app is a two-step process:

1. Approve and Add Unitech OEMConfig to the Hexnode inventory
2. Configure Unitech-specific settings

Approve and Add Unitech OEMConfig to the Hexnode inventory
----------------------------------------------------------

To add the Unitech OEMConfig app to the Hexnode inventory,

1. Go to **Apps** > **+ Add Apps** > **Managed Google Apps**.
2. Search the [Unitech OEMConfig app](https://play.google.com/work/apps/details?id=com.unitech.oemconfig) and select it.
3. Click **Approve**. This action will take you to the **Approval Settings** page, where you can select the method by which you would like to handle new app permission requests.
4. Navigate to the **Notifications** tab, where you can provide your email addresses to get notified when the OEMConfig app requests new app permissions. Click **Add**.
5. Click **Done** to add the app to the app inventory.
6. Next, [distribute these approved apps to the target devices](https://www.hexnode.com/mobile-device-management/help/install-android-app/).

Configure Unitech-specific settings
-----------------------------------

To configure Unitech-specific settings on devices,

1. Head on to **Policies**.
2. Create a new policy with the **New Policy** button or continue with an existing policy. Provide a suitable name and description (optional) for the policy.
3. Go to **Android** > **App Management** > **App Configurations** > **Configure**.
4. Click the **+Add new configuration** button.
5. Select the **Unitech OEMConfig** app from the list. Configure the following settings available on the OEMConfig app: Clock Settings
    
     SettingsDescriptionClock ActionSpecify whether to configure the clock’s settings, including the date, time, and time zone.Time ModeSet the time mode as either *Auto* (network-provided time) or *Manual*.Manual DateIf the ‘Time Mode’ is set to ‘Manual’, enter the date in the format dd/MM/yyyy.Manual TimeIf the ‘Time Mode’ is set to ‘Manual’, enter the time in the format HH:mm.Time Zone ModeSet the time zone as either *Auto* (network-provided time zone) or *Manual*.Manual Time ZoneIf Time Zone Mode is set to Manual, enter the time zone that must be an [Olson ID](https://en.wikipedia.org/wiki/List_of_tz_database_time_zones#List), like America/Chicago, Canada/Central, and so on.Time FormatSet the time either to 12 or 24-hour format.
    
     
    
     
    
    Display Settings
    
     SettingsDescriptionDisplay ActionSpecify whether to configure the display settings that include the screen’s brightness, font size, rotation settings, and more.Display TimeoutSet the amount of idle time before the device is locked automatically. You can choose from the following values: 
    - Never
    - 15 seconds
    - 30 seconds
    - 1 minute
    - 2 minutes
    - 5 minutes
    - 10 minutes
    - 30 minutes
    
    Stay AwakeEnable this option to keep your device’s screen awake all the time.Display Font SizeSet the size of the characters that are displayed on the screen. The available sizes include: 
    - Default
    - Small
    - Large
    - Largest
    
    Back Light LevelSet the screen backlight brightness between 0 and 255.Auto BrightnessEnable this option to turn on automatic brightness mode.Auto RotateEnable this option to automatically rotate your screen when you move your device between portrait and landscape.
    
     
    
     
    
    NFC Settings
    
     SettingsDescriptionNFC ActionSpecify whether to configure NFC settings.NFC AdapterEnable this option to turn on NFC Adapter.
    
     
    
     
    
    FOTA Settings
    
     SettingsDescriptionFota ActionSpecify whether to configure Firmware Over-The-Air (FOTA) settings.Fota OS Update File PathEnter the OS update file path (e.g., *.zip).
    
     
    
     
    
    General Settings
    
     SettingsDescriptionGeneral UI ActionSpecify whether to configure general settings on your Unitech devices.System LanguageEnter the [language tags](https://en.wikipedia.org/wiki/Language_localisation#Language_tags_and_codes) such as zh-TW, en-US, en-CN, etc., to be added as the system language.IME Current KeyboardEnter the package name of the input method editor (IME) app.
    
     
    
     
    
    Keymap Settings
    
     SettingsDescriptionKeymap ActionSelect the option required to configure the keymap settings. The available options include: 
    - None
    - Enable mappings
    - Disable mappings
    - Reset mappings
    - Import mappings
    - Export mappings
    
    Folder PathEnter the path of the keymap folder.Programmable KeysSpecify the below programmable key settings: 
    - Key Name
    - Key Code
    - Wake Up
    - Broadcast Key Down Action
    - Keymap Broadcast Down Extras
    - Broadcast Key Up Action
    - Keymap Broadcast Up Extras
    - Keymap Start Activity Extras
    
     Add Group  Click the button if more than one key is to be programmed. 
    
     
    
     
    
    Power Settings
    
     SettingsDescriptionPower ActionSpecify whether to configure the power settings. The available options include: 
    - None
    - Reboot
    - Reset
    
    
    
     
    
     
    
    Wireless General Settings 
    
     SettingsDescriptionWireless General ActionSpecify whether to configure wireless settings on the devices.Location ModeEnable this option to turn on location services on the devices.
    
     
    
     
    
    WLAN Settings 
    
     SettingsDescriptionWLAN ActionChoose whether to set or remove WLAN profiles. The available configurations include: 
    - None
    - Set Profile
    - Remove Profile
    - Remove All Profiles
    
    SSIDEnter the name of the network.PasswordEnter the password to connect to the network.Security ModeSelect the encryption type to use when connecting to the network. The available modes include: 
    - None
    - WEP
    - WPA
    
    IP AssignmentSelect the IP assignment as either Dynamic Host Configuration Protocol (DHCP) or Static IP address.Static IP AddressIf ‘IP Assignment’ is set to ‘Static’, enter the Static IP address.Static IP Mode – Prefix LengthEnter the initial bits of the address (prefix) for the destination IP.Static IP Mode – GatewaySpecify the IP address of the default gateway for the provided static IP address.Static IP Mode – DNS Server 1Enter the IP address of your DNS server.Static IP Mode – DNS Server 2Enter the IP address of your additional DNS server.Proxy ModeSelect the proxy mode as None, PAC, or Static.Proxy – PAC Mode – PAC file URLIf ‘Proxy Mode’ is set to ‘PAC’, enter the PAC file URL.Proxy – Static Mode – Host URLIf ‘Proxy Mode’ is set to ‘Static’, enter the host URL of the proxy server.Proxy – Static Mode – PortIf ‘Proxy Mode’ is set to ‘Static’, enter the port number of the proxy server.Proxy – Static Mode – Excusive ListSpecify the excusive list if the ‘Proxy Mode’ is set to ‘Static’.
    
     
    
     
    
    WLAN Advanced Settings
    
     SettingsDescriptionwlanadvanced ActionWLAN Advanced can improve the roaming behavior of devices when they’re in areas of low coverage. Choose the required option from the below settings: 
    - None
    - Import
    - Export
    - NewSetting
    
    wlanadvanced Settings Folder PathSpecify the path of the WLAN Advanced settings folder. The path is of the form “/sdcard/wlanadvanced/”Power Save Mode (0 or 1)(0:Disable, 1:Enable)Enter the value “1” to enable the power save mode. It sets the Wi-Fi module to its optimum power consumption setting. If you need to disable it, type in “0”.Roaming Trigger (-10 dBm ~ -120 dBm) (input 10 mean -10)Enter the roaming trigger value in dBm. If the signal strength is lower than this specified value, the roaming trigger will scan for stronger and better access points.Roaming Delta (0 dB ~ 30 dB)Enter the roaming delta value in dBm based on which the device will roam to a better signal strength access point.Roaming Scan Period (0 ms ~ 60000 ms)Enter the roaming scan period based on which the device will continue with the existing access point before it roams to a different access point.
    
     
    
     
    
    Scanner Settings
    
     SettingsDescriptionScanner ActionSpecify whether to configure scanner settings. The available options include: 
    - None
    - Import
    - Export
    
    Scanner Settings Folder PathSpecify the path of the scanner settings folder. e.g. /sdcard/scanner/
    
     
    
     
    
    Device Management Capabilities
    
     SettingsDescription Device Capability Enabled  Use this option to enable or disable device capability.Device Capability Item Use this feature to enable/disable various device capabilities such as: 
    - Camera
    - GPS
    - Touch Scanner
    - Bluetooth
    - Keyboard
    - USB
    - WLAN
    - WWAN
    - Flash
    - Ime
    
     Add group  Click the button if more than one feature is to be enabled/disabled.
    
     
    
     
    
    ELauncher Settings
    
     SettingsDescriptionELauncher ActionELauncher is a software to install and run specified programs on device startup. You can select one of the below options: 
    - None
    - Enable ELauncher
    - Disable ELauncher
    
    Set Kiosk AppEnter the package name of an app to be set as the kiosk app.Launcher App ListEnter the package name of the apps to be shown on the launcher list. Separate multiple apps with commas (,).Launcher WallpaperSpecify the path of the wallpaper on the device to be set as the launcher wallpaper.ELauncher PIN CodeEnter the PIN code for the ELauncher software.ELauncher Kiosk ModeEnable this option to turn on kiosk mode.
    
     
    
     
    
    MoboLink Settings
    
     SettingsDescriptionMoboLink ActionSpecify whether to configure MoboLink agent settings. MoboLink is an agent app that can be used to manage Unitech devices.MoboLink Server URLEnter the URL of the MoboLink server.Autorun on BootupEnable or disable autorun on bootup.Rebootstrap on BootupEnable or disable rebootstrap on bootup.Silent ModeEnable or disable silent mode.Show Connection NotificationsEnable this option to display connection notifications.Show Event NotificationsEnable this option to display event notifications.Lock SettingsEnable or disable lock settings.
    
     
    
     
    
    Unitech Scanner Utility Settings
    
     SettingsDescriptionEnable/Disable scanner trigger keySpecify whether to enable or disable the trigger keys.Enable/Disable data ack/nakSpecify whether to enable or disable the data characters used to ‘acknowledge’ or ‘not acknowledge’ the receipt of the data without error.Enable/Disable auto connectSpecify whether to enable or disable auto-connect.UPC-ASpecify whether to enable or disable the UPC-A barcode.UPC-ESpecify whether to enable or disable the UPC-E barcode.UPC-E1Specify whether to enable or disable the UPC-E1 barcode.EAN-8/JAN-8Specify whether to enable or disable the EAN-8/JAN-8 barcode.EAN-13/JAN-13Specify whether to enable or disable the EAN-13/JAN-13 barcode.Bookland EANSpecify whether to enable or disable the Bookland EAN (any EAN that begins with the 978 prefix) barcode.Bookland ISBN FormatSelect one of the following formats for Bookland data: 
    - Bookland ISBN-10
    - Bookland ISBN-13
    
    ISSN EANSpecify whether to enable or disable ISSN EAN.Decode UPC/EAN/JAN SupplementalsSelect one of the below options to decode UPC/EAN/JAN Supplementals: 
    - Decode UPC/EAN/JAN Only With Supplementals
    - Ignore Supplementals
    - Autodiscriminate UPC/EAN/JAN Supplementals
    - Enable 378/379 Supplemental Mode
    - Enable 978/979 Supplemental Mode
    - Enable 977 Supplemental Mode
    - Enable 414/419/434/439 Supplemental Mode
    - Enable 491 Supplemental Mode
    - Enable Smart Supplemental Mode
    
    Transmit UPC-A Check DigitEnable or disable this option to transmit the symbol with or without the UPC-A check digit.Transmit UPC-E Check DigitEnable or disable this option to transmit the symbol with or without the UPC-E check digit.Transmit UPC-E1 Check DigitEnable or disable this option to transmit the symbol with or without the UPC-E1 check digit.UPC-A PreambleSelect one of the following options required to transmit UPC-A preamble to the host device: 
    - No Preamble ([DATA])
    - System Character ([SYSTEM CHARACTER] [DATA])
    - System Character + Country Code ([COUNTRY CODE] [SYSTEM CHARACTER] [DATA])
    
    UPC-E PreambleSelect one of the following options required to transmit UPC-E preamble to the host device: 
    - No Preamble ([DATA])
    - System Character ([SYSTEM CHARACTER] [DATA])
    - System Character + Country Code ([COUNTRY CODE] [SYSTEM CHARACTER] [DATA])
    
    UPC-E1 PreambleSelect one of the following options required to transmit UPC-E1 preamble to the host device: 
    - No Preamble ([DATA])
    - System Character ([SYSTEM CHARACTER] [DATA])
    - System Character + Country Code ([COUNTRY CODE] [SYSTEM CHARACTER] [DATA])
    
    Convert UPC-E to UPC-ASelect ‘Enable’ to convert UPC-E decoded data to UPC-A format before transmission. Else, choose ‘Disable’ to transmit UPC-E decoded data as UPC-E data without conversion.Convert UPC-E1 to UPC-ASelect ‘Enable’ to convert UPC-E1 decoded data to UPC-A format before transmission. Else, choose ‘Disable’ to transmit UPC-E1 decoded data as UPC-E1 data without conversion.Code 128Choose whether to enable or disable the Code 128 symbology.Code 128 Length Parameter 1Set the Code 128 length 1 from 0 to 55.Code 128 Length Parameter 2Set the Code 128 length 2 from 0 to 55.GS1-128Enable or disable GS1-128 symbology.ISBT 128Enable or disable ISBT 128, a variant of Code 128.Code 39Enable or disable Code 39 symbology.Trioptic Code 39Enable or disable Trioptic Code 39, a variant of Code 39.Convert Code 39 to Code 32Enable or disable converting Code 39 to Code 32. Note that Code 39 must be enabled for this setting to function.Code 32 PrefixEnable or disable adding the prefix character “A” to all Code 32 bar codes.Code 39 Length Parameter 1Set the Code 39 length 1 from 0 to 55.Code 39 Length Parameter 2Set the Code 39 length 2 from 0 to 55.Code 39 Check Digit VerificationEnabling this option will check the integrity of all Code 39 symbols. Thus, you can ensure data compliance with the specified check digit algorithm.Transmit Code 39 Check DigitEnabling this option will transmit the Code 39 check digit with the data.Code 39 Full ASCII ConversionEnable this option to allow Code 39 – Full ASCII symbology.Code 93Enable or disable the Code 93 symbology.Code 93 Length Parameter 1Enter the Code 93 length 1 from 0 to 55.Code 93 Length Parameter 2Set the Code 93 length 2 from 0 to 55.Code 11Enable or disable the Code 11 symbology.Code 11 Length Parameter 1Enter the Code 11 length 1 from 0 to 55.Code 11 Length Parameter 2Set the Code 11 length 2 from 0 to 55.Code 11 Check Digit VerificationSpecify the option required to check the integrity of all Code 11 symbols. Thus, you can ensure data compliance with the specified check digit algorithm. The available options are: 
    - Disable
    - One Check Digit
    - Two Check Digits
    
    Transmit Code 11 Check DigitEnable this option to transmit the Code 11 check digit(s). This feature works only if ‘Code 11 Check Digit Verification’ is enabled.Interleaved 2 of 5Enable or disable Interleaved 2 of 5.Interleaved 2 of 5 Length Parameter 1Set the Interleaved 2 of 5 length 1 from 0 to 55.Interleaved 2 of 5 Length Parameter 2Set the Interleaved 2 of 5 length 2 from 0 to 55.Interleaved 2 of 5 Check Digit VerificationSelect the algorithm to check the integrity of an Interleaved 2 of 5 symbol. You can select one of the below options: 
    - Disable
    - USS Check Digit
    - OPCC Check Digits
    
    Transmit Interleaved 2 of 5 Check DigitEnable this option to transmit the Interleaved check digits with the data.Convert I 2 of 5 to EAN-13Selecting the ‘Enable’ option will convert I 2 of 5 codes to EAN-13 and transmit to the host as EAN-13.Discrete 2 of 5Enable or disable Discrete 2 of 5.Discrete 2 of 5 Length Parameter 1Set the Discrete 2 of 5 length 1 from 0 to 55.Discrete 2 of 5 Length Parameter 2Set the Discrete 2 of 5 length 2 from 0 to 55.CodabarEnable or disable Codabar barcodes.Codabar Length Parameter 1Set the readable length 1 of Codabar from 1-55.Codabar Length Parameter 2Set the readable length 2 of Codabar from 1-55.CLSI EditingEnable this setting to strip the start and stop characters and insert a space after the 1st, 5th, and 10th characters of a Codabar symbol.NOTIS EditingAllow this option to strip the start/stop characters from a decoded Codabar symbol.MSIEnable or disable MSI barcode symbology.MSI Length Parameter 1Set the MSI length 1 from 0 to 55.MSI Length Parameter 2Set the MSI length 2 from 0 to 55.MSI Check DigitVerify the integrity of the data by selecting one from the below options: 
    - One MSI Check Digit
    - Two MSI Check Digits
    
    Transmit MSI Check DigitEnable this option to transmit the check digits with the data.MSI Check Digit AlgorithmIf ‘MSI Check Digit’ is set to ‘Two MSI Check Digits,’ select the algorithm required to check the integrity of the data as additional verification. You can choose either MOD11/MOD10 or MOD10/MOD10 algorithm.Chinese 2 of 5Enable this option to allow Chinese 2 of 5 symbology.Matrix 2 of 5Enable this option to allow Matrix 2 of 5 symbology.Matrix 2 of 5 Length Parameter 1Set the Matrix 2 of 5 length 1 from 0 to 55.Matrix 2 of 5 Length Parameter 2Set the Matrix 2 of 5 length 2 from 0 to 55.Matrix 2 of 5 Check DigitEnable this option to check the integrity of Matrix 2 of 5 code.Transmit Matrix 2 of 5 Check DigitEnable this option to transmit the check digit with the data.Inverse 1DSet the 1D inverse decoder setting as: 
    - *Regular Only*: Decodes regular 1D barcodes only.
    - *Inverse Only*: Decodes inverse 1D barcodes only.
    - *Inverse Autodetect*: Decodes both regular and inverse barcodes.
    
    US PostnetEnable or disable US Postnet.US PlanetEnable or disable US Planet.Transmit US Postal Check DigitSelect whether to transmit US Postal data with or without the check digit.UK PostalEnable or disable UK Postal.Transmit UK Postal Check DigitSelect whether to transmit UK Postal data with or without the check digit.Japan PostalEnable or disable Japan Postal.Australia PostalEnable or disable Australia Postal.Netherlands KIX CodeEnable or disable Netherlands KIX Code.USPS 4CB/One Code/Intelligent MailEnable or disable USPS 4CB/One Code/Intelligent Mail.UPU FICS PostalEnable or disable UPU FICS Postal.GS1 DataBarEnable this option to allow GS1 DataBar symbology.GS1 DataBar LimitedEnable this option to allow GS1 DataBar Limited.GS1 DataBar ExpandedEnable this option to allow GS1 DataBar Expanded.Convert GS1 DataBar to UPC/EANSelect ‘Enable’ to strip the leading ‘010’ from DataBar symbols and convert the barcode to EAN-13.Composite CC-CEnable this option to allow GS1 DataBar composite CC-C.Composite CC-A/BEnable this option to allow GS1 DataBar composite CC-A/B.Composite TLC-39Enable or disable Composite barcodes of type TLC-39.UPC Composite ModeChoose whether to link UPC symbols with a 2D symbol during transmission. 
    - *UPC Never Linked*: Transmit UPC barcodes without linking a 2D symbol even if it’s present.
    - *UPC Always Linked*: Transmit UPC barcodes only by linking the 2D portion. If it is not present, the bar code will not be transmitted.
    - *Autodiscriminate UPC Composites*: The engine checks the presence of a 2D symbol, then transmits the UPC, along with the 2D symbol if present.
    
    PDF417Enable this option to allow PDF 417 barcode format.MicroPDF417Enable this option to allow Micro PDF symbology.Code 128 EmulationEnable this option to allow Code 128 symbology.Data MatrixEnable this option to allow Data Matrix.Data Matrix InverseSelect the setting to decode Data Matrix: 
    - *Regular*: Decodes regular Data Matrix barcodes only.
    - *Inverse Only*: Decodes inverse Data Matrix barcodes only.
    - *Inverse Autodetect*: Decodes both regular and inverse Data Matrix barcodes.
    
    MaxicodeEnable or disable Maxicode.QR CodeEnable or disable QR Code.MicroQREnable this option to allow Micro QR barcode.AztecEnable this option to allow Aztec barcodes (2-D matrix symbology).Aztec InverseSelect the option needed to decode Aztec. The available options include: 
    - *Regular*: Decodes regular Aztec barcodes only.
    - *Inverse Only*: Decodes inverse Aztec barcodes only.
    - *Inverse Autodetect*: Decodes both regular and inverse Aztec barcodes.
    
    Han XinEnable this option to allow Han Xin code.Han Xin InverseSelect a Han Xin inverse decoder setting: 
    - *Regular*: Decodes Han Xin barcodes with normal reflectance only.
    - *Inverse Only*: Decodes Han Xin barcodes with inverse reflectance only.
    - *Inverse Autodetect*: Decodes both regular and inverse Han Xin barcodes.
    
    Trigger ModesSelect a trigger mode from the below options: 
    - Level
    - Presentation Mode
    - Host
    - Auto Aim
    - Auto Aim with Illumination
    
    Picklist ModeSelect the picklist mode required to decode a barcode from multiple barcodes printed close together: 
    - Disabled Always
    - Enabled Always
    
    Transmit Code ID CharacterA Code ID Character determines the code type of a scanned barcode. The available options include: 
    - Symbol Code ID Character
    - AIM Code ID Character
    - None
    
    Decode Session TimeoutEnter the maximum time decode processing during a scan attempt from 5 to 99 (0.5 to 9.9 seconds).Low Light Motion Detection AssistSelect the mode to detect motion in dim to dark light environments: 
    - *Disable*: Both Aiming Dot and Dim Illumination are turned off.
    - *Enable Aiming Dot*: Dim Illumination is off, but the Aiming Dot is on to assist in scene detection.
    - *Enable Dim Illumination*: The Aiming dot is off, but Dim Illumination is on to assist in scene detection.
    
    BT Signal Checking LevelSet up Bluetooth configuration from the below settings: 
    - Normal Level
    - Higher Level
    
    Scanned data formatSelect the required scan data transmission format as: 
    - Raw(without code type)
    - SSI(with code type)
    
    Data TerminatorSet up terminator as: 
    - None/Null
    - CR
    - LF
    - CRLF
    - TAB
    
    Unitech Scanner Utility ItemUse this feature to set up various Unitech Scanner Utility items such as: 
    - None
    - Export settings
    - Import settings
    - Upload settings
    
    
    
     
    
     
    
    RFID2Key Settings
    
     SettingsDescriptionRFID2Key ActionSelect the RDIF2Key action as: 
    - None
    - Export settings
    - Import settings
    - Reset settings
    - Set Mode
    
    Configuration File PathSpecify the path of the configuration file.Password CodeEnter the password code.RFID to Key (mode)Enable or disable RFID to Key (mode).
    
     
    
     
    
    Software Update Settings 
    
     SettingsDescriptionSoftware Update ActionSelect the software update action as: 
    - None
    - Import Settings
    - Export Settings
    - Reset Settings
    - Set Settings
    
    Configuration File PathSpecify the path of the configuration file.Set Operation ModeSet the mode of operation as: 
    - Normal Mode
    - Auto Mode
    - Auto Silent Mode
    - Disable
    
    Set Update Policy – Installed AppsSpecify whether installed apps are to be updated. The available values are: 
    - All
    - None
    - Selected
    
    Set Update Policy – Installed Apps ListEnter the name of the apps that you wish to update. Separate multiple apps with commas (,).Set Update Policy – New AppsSet the update policy for new apps as either Install or None.Set PasscodeEnter a passcode.Set Server URLSpecify the server URL.
    
     
    
     
    
    StageGO Settings
    
     SettingsDescriptionStageGO ActionSpecify whether to configure StageGO settings. StageGo is a software used to set up multiple devices with a single configuration.Report PathSpecify the report path.Max Number of ReportEnter the maximum number of allowed reports.Enable/Disable Bootup ScriptSpecify whether to enable/disable scripts on bootup.Bootup Scripts File PathIf bootup scripts are enabled, specify the path of scripts. Split multiple scripts using commas (,).Setting Menu PasscodeEnter a passcode to be set as the Setting Menu passcode.Scan ModeSet the scan mode as either CameraMode or ScannerMode.
6. Click **Done** after configuring the required settings.
7. Next, associate the policy with the target devices by navigating to the **Policy Targets** tab.
8. Select the required **Devices**/**Device Groups**/**Users**/**User Groups**/**Domains** and click **Save**.

 Note: The OEM specific-settings explained in this document are based on the configurations set by the respective OEM vendors, which may vary frequently. Since Hexnode is not solely responsible for setting up these configurations, you may find slight variations in the settings displayed on the portal from this document.