OEMConfig is a device management feature for customizing device-specific settings on Android Enterprise enrolled devices. This solution provides users access to all the latest Datalogic OEMConfig features as it gets released. Datalogic OEMConfig is an OEMConfig app that allows you to remotely configure Datalogic device settings from the UEM console.

 Pre-requisites:2. Datalogic devices running Android 8.0 and above.
3. The devices and organization enrolled in the [Android Enterprise program](https://www.hexnode.com/mobile-device-management/help/how-to-enroll-organization-in-android-enterprise-using-hexnode-mdm/).
 

Add and approve the app to the Hexnode inventory
------------------------------------------------

First, you must approve the **Datalogic** app to add the app to the Hexnode app inventory.

1. Navigate to the **Apps** tab.
2. Click on the **+Add apps** button and select **Managed Google Apps** from the drop-down list.
3. Search for the [**Datalogic OEMConfig**](https://play.google.com/store/apps/details?id=com.datalogic.settings.oemconfig&hl=en_US&gl=US) app and click on **Approve**.
4. Next, a pop-up window arises, go through the permission required for the app and click **Approve** to finalize.
5. You will be directed to a page showing the approval settings and the tab notifications. Configure the settings accordingly and click on **Done**.

This will add the Datalogic app to the Hexnode app inventory. Now, you can [deploy](https://www.hexnode.com/mobile-device-management/help/install-android-app/#install-apps-via-remote-actions) the app to the target devices.

Set-up OEM Configurations
-------------------------

To enable OEM Configurations on your Android Enterprise devices

1. Go to the **Policies** tab.
2. Create a new policy using the **New Policy** button or select an existing policy.
3. Navigate to **Android > App Management > App Configurations**.
4. Click on **Configure** and **+ Add new configuration** button.
5. Select the **Datalogic OEMConfig** app from the list of approved apps.
6. From the app configuration screen displayed, configure the required settings.
You’ll have the following features to be configured.

Scanner Settings

Configure settings of device scanner.

Notifications and Formatting

 OEMConfig SettingsDescriptionGood Read DurationDuration of each notification after a successful read (in msec). Range 20 – 500. Default value is 70msec.Good Read IntervalDelay between notifications on a successful read (in msec) Range 20 to 500. Default value is 20msec.Good read numberThe number of notifications produced after a successful read. Range 1 – 4. The default value is 1.Enable display notificationDisplay a toast message on a successful read. Default value is false.Good read audio modeSelect scanner audio notification mode. You can choose from None, Beep Tone (Default), Audio file.Default good read audio file selectionSelect the file used for the audio notification on a successful read chosen from list of Factory audio tones. Default value is Scan Sound.Custom good read audio file path Provide path to the custom file used for the audio notification on a successful read. If a custom path is invalid or not specified, the default audio file will be used.Good read audio volumeSpecify the volume of the audio notification on a successful read. Range 0–100. Default value is 75.Enable good readNotify when a scan is successful using automatic good read. The default value is true.Enable Green SpotEnable Green Spot notification when a scan is successful. The default value is true.Enable good read LEDEnable LED notification when a scan is successful. Default value is true.Enable vibratorEnable the device to create a vibration notification when a scan is successful. Default value is false.Label PrefixString of Unicode characters sent prior to the symbology identifier. Label prefix may contain printable and non-printable characters. Represent non-printable characters inside square brackets. E.g. [ESC]. For more info check out www.asciitable.com.Label suffix String of Unicode characters sent after the symbology identifier. Label suffix may contain printable and non-printable characters. Represent non-printable characters inside square brackets. E.g. [LF]. For more info check out www.asciitable.com.Group Separator ReplacementString of Unicode characters that replaces each occurrence of GS in the scanned data. Label prefix may contain printable and non-printable characters. Represent non-printable characters inside square brackets. E.g. [BS][TAB]. For more info check out www.asciitable.com.Remove non-printable charactersRemove all non-printable characters from the scanned data. The length check for each symbology is evaluated before any characters are removed. Characters in the code ID, prefix, suffix, and separator won’t be removed. Default value is false.Send code IDSelect symbology identifier to be transmitted along with the scanned data. You can choose from None (default), DLM identifier before, AIM identifier before, User defined identifier before, DLM identifier after, or User defined identifier after.

 

 

Scanner Options and Wedge

 OEMConfig SettingsDescriptionEnable PicklistLimit reading to a targeted selection. Disabled by default.Enable illuminationIlluminate barcode when capturing frames. Enabled by default.Illumination Type (If Enable illumination option is enabled) Select the scanner illuminator when it attempts to read. You can choose from Auto (default), Red, or White.Enable aimSet projection aim when capturing frames. Enabled by default.Display mode Manage barcode illumination when capturing frames from displays or reflective surfaces. Disabled by default.
If enabled the illuminator adjusts according to reflection in previous frames.
If disabled the illuminator doesn’t adjust and always stays enabled.Image Capture Profile Select the image capture profile used by the scanner. You can choose between Auto by enabled symbologies(default), Motion tolerance, Reflection tolerance, or Custom.Custom image capture profile (Select **Custom** in **Image Capture Profile** for this value to have an effect) Set the frame brightness for the Custom Image Capture Profile. Range 0- 255.Target modeSelect the beam mode of scanner target. You can choose from No Delay (default), Spot timeout, or Release scan.Target timeout (Select **Target mode** to **Spot Timeout** for this value to have an effect.)Select the time (in seconds) the target beam is ON before the scanner attempts to read.Release Scan timeout (Select **Target mode** to **Release Scan** for this value to have an effect.)Select the maximum time (in seconds) that the scanner is on after trigger release. Default value is 2 seconds.Decode timeout (Select **Target mode** to **Spot Timeout** or **No Delay** for this value to have an effect.)Select the maximum time (in seconds) that the scanner remains on without reading a barcode. Default value is 5.0 seconds.Enable multi scanCapture multiple labels sequentially. Disabled by default.Number of required labels (Enable multi scan option must be enabled for this value to have an effect)Set the number of labels to be read before automatically ending a good read transaction. The decoding session is ended successfully and all the collected labels are returned together, only if the label count is reached. Number of labels must be between 2 and 10.Enable single notification (**Enable multi scan** option must be enabled for this value to have an effect)Notify on each successful read during a multi scan operation. Disabled by disabled.Enable keyboard wedgeSend the captured data to the foreground application in the form of key events. Enabled by default.Enable keyboard wedge only on focus (**Enable keyboard wedge** must be enabled for this value to have an effect)Send the captured data as key events to the current text area with active keyboard input. Disabled by default.Keyboard wedge input mode (**Enable keyboard wedge** must be enabled for this value to have an effect) Select input mode for keyboard wedge. You can choose from Text Injection, Key Pressure, Commit Text.Enable intent wedge Send the captured data to an application in the form of an implicit intent. Disabled by default.Intent delivery modeSelect delivery mode for intent wedge. You can choose from Send via Start Activity, Send via Start Service, or Broadcast Intent (default).Intent actionSet the general action to be performed. Default value is **com.datalogic.decodewedge.decode_action**.Intent category Set the intent category. Default value is **com.datalogic.decodewedge.decode_category**.Intent extra barcode string Set key corresponding to extra data. Default value is **com.datalogic.decode.intentwedge.barcode_string**.Intent extra barcode typeSet an explicit MIME data type. Default value is **com.datalogic.decode.intentwedge.barcode_type**.Intent extra barcode dataSet the data this intent is operating on. Default value is **com.datalogic.decode.intentwedge.barcode_data**.Enable web wedgeSend the captured data in the form of a valid URL to the Internet browser.

 

 

Symbology Settings

### Barcode

The symbology for each barcode can be additionally customized with settings that may affect that specific barcode decoding.

#### Australia Post

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Australia post. By default, this is set as false.User IDSpecify the symbology identifier, if any. By default, the value is set as f.#### Aztec Code

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Aztec code. By default, this is set as true.User IDSpecify the symbology identifier, if any. By default, the value is set as d.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. By default, this is 1. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. By default, this is 3750. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.Character set modeUse this option to control the character set that can be used for the decoded label. By default, this is Windows-1252 Latin1.#### Codabar

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Codabar. Default value is true.User IDSpecifies the symbology identifier if any. Default value is I.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. By default, this is 4. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. Default value is 20. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.Enable checksumIf enabled, the use of checksum characters will be made required to verify a barcode. By default this is false.Send checksumIf enabled, includes checksum in the label transmission. For this to take effect, the option **Enable checksum** should be enabled.Send start/stopCheck this to enable the transmission of the decoded start and stop characters. Default value is false.Convert to CLSIIf enabled, only the read labels that conform to CLSI specifications will be allowed to decode. Default value is false.#### Code 128

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code 128. Default value is true.User IDSpecifies the symbology identifier if any. Default value is K.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. By default, this is 2. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. Default value is 40. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.AggressivenessThis parameter controls the level of aggressiveness in decoding the Code 128 symbology. The available values are Very Low, Low, Medium (default), High, and Very High.#### [Code 128] GS1–128

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code GS1-128. Default value is true.User IDSpecifies the symbology identifier if any. Default value is o.#### [Code 128] ISBT 128

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code ISBT 128. Default value is false.User IDSpecifies the symbology identifier if any. Default value is K.ModeUse this field to specify the allowed ISBT 128 barcode symbologies. The available values are Single (default), Concatenated, and Both.Concatenated list enableEnable to allow concatenation of commonly concatenated pairs. Default value is true. This option can only be configured if the **Mode **is Concatenated or Both.****#### Code 39

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code 39. Default value is true.User IDSpecifies the symbology identifier if any. Default value is C.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. By default, this is 1. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. Default value is 20. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.Enable checksumIf enabled, the use of checksum characters will be made required to verify the barcode. By default this is false.Send checksumIf enabled, includes checksum in the label transmission. For this to take effect, **Enable checksum** should be true.Full ASCII conversionCheck to enable full ASCII conversion. Default value is false.#### [Code 39] Code 32

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code 32. Default value is false.User IDSpecifies the symbology identifier if any. Default value is Y.#### [Code 39] Tri-Optic

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Tri-Optic. Default value is false.User IDSpecifies the symbology identifier if any. Default value is X.#### Code 93 

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Code 93. Default value is false.User IDSpecifies the symbology identifier if any. Default value is L.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. By default, this is 2. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. Default value is 20. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.#### Composite

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Composite. Default value is false.User IDSpecifies the symbology identifier if any. Default value is q.Convert to GS1–128Check this option to enable the conversion of the composite label to a sequence of GS1-128 barcodes. The default value is false.UPC/EAN link modeThe available values are Auto (default), Always linked, Never linked. This field controls UPC/EAN label recognition mode.#### Data Matrix

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Data Matrix. Default value is true.User IDSpecifies the symbology identifier if any. Default value is V.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. By default, this is 1. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. Default value is 1500. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.Character set modeUse this option to control the character set that can be used for the decoded label. By default, this is Windows-1252 Latin1.Data Matrix operating modeThis field value controls the operating mode. The available values are Very Fast, Fast (default), Robust, and Very Robust.#### Digimarc

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Digimarc. Default value is true.#### Discrete 2 of 5

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Discrete 2 of 5. Default value is false.User IDSpecifies the symbology identifier if any. Default value is F.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. By default, this is 6. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 99. Default value is 10. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.#### Dotcode

OEMConfig SettingsDescriptionEnableCheck to enable the symbology for Dotcode. Default value is false.User IDSpecifies the symbology identifier if any. Default value is d.Length controlSelect the length control mode for a label. The available values are No check, One fixed, Two fixed, and Range (default).L1 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. By default, this is 1. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.L2 lengthThis is one of the two configurable label lengths. Enter an integer between 1 and 9999. Default value is 7000. For this length to have an effect **Length control** must be One fixed, Two fixed, or Range.Character set modeUse this option to control the character set that can be used for the decoded label. By default, this is Windows-1252 Latin1.You can also configure other barcode symbology settings such as GS1 DataBar Expanded, GS1 DataBar Limited, GS1 DataBar-14, Interleaved 2 of 5, Japan Post, Matrix 2 of 5, MaxiCode, Micro PDF417, Micro QR Code, MSI, PDF417, PostNL KIX-code, QR Code, UK Royal Mail, UPC/EAN Extensions, UPC-A, UPC-E, USPS Intelligent Mail, USPS PLANET and USPS POSTNET.

 

 

 

Advanced Symbology Settings

#### Advanced Barcode Options

OEMConfig SettingsDescriptionEnable UPC/EAN reducedIf enabled, allows the decoding of UPC/EAN labels with short margins. Default value is false.Enable Code 39 reducedIf enabled, allows the decoding of Code 39 labels with short margins. The default value is false.Enable Code 128 reducedIf enabled, allows the decoding of Code 128 labels with short margins. The default value is false.Enable MSI reducedIf enabled, allows the decoding of MSI labels with short margins. The default value is false.1D invertedSet the inverse mode for linear barcode symbologies. The available values are Regular (default), Reverse and Both.2D invertedSet the inverse mode for 2D barcode symbologies. The available values are Regular, Reverse and Both (default).

 

 

Power and Charging

 OEMConfig SettingsDescriptionSuspend on external powerSet the screen timeout for when the device is connected to an external power source. Default value is 5 minutes. Suspend on internal powerSet the screen timeout for when the device is running on battery power. Default value 1 minute.Battery saver enableCheck to immediately enable battery saver mode on the device. On Android 8, rebooting or connecting to a charging source might reset this setting. Disabled by default.Battery saver auto enableEnable to automatically turn on battery saver mode on the device when the battery falls below a specific level. Disabled by default.Battery saver trigger levelSet the trigger level (in battery percentage) below which the battery saver mode will be auto enabled. The device may scale this value to the closest valid option depending on the Android version. The default value is 5.Battery saver auto disable [Android 10+]Enable this option to automatically disable battery saver on Android 10 or later devices when the battery is above 90%. Enabled by default.Wakeup SourceSelect the wakeup source to enable/disable. You can choose from None (default), Left trigger, Right trigger, Pistol trigger, or Front trigger.Enable Enables the selected wakeup source. Enabled by default.Charging profile Select the wireless charging profile used to manage the charging preferences. This setting is persistent through reboots and factory resets. Default value is Speed and capacity preferences. 

 

 

Keyboard and Scan Buttons

 OEMConfig SettingsDescriptionLock key inputRestricts input from keyboard and physical buttons. Disabled by default. Trigger sourceSelect the physical trigger source to enable/disable. You can choose from None (default), Left trigger, Right trigger, Pistol trigger, or Front trigger.EnableEnables the selected trigger source. Enabled by default.Auto scan enableIf checked, you can specify the range at which the auto scan feature begin scanning. Disabled by default.Auto scan rangeSpecify the sensitivity limit at which an object should trigger the auto scan feature. The available options are Near (default), Intermediate, and Far.Source keyScan code corresponding to the desired key to remap. Default value is None.Remap typeSelect the type of remapping. You can choose from Keycode (default), Unicode, or Start Activity.[Keycode] Target key (Remap type must be Keycode for this value to have an effect.) Select the keycode corresponding to the desired remap function. The default value is 0. [Keycode] Android meta state (Remap type must be Keycode for this value to have an effect.) Select the Android meta state to apply to desired remap function. The default value is None.[Unicode] Character (Remap type must be Unicode for this value to have an effect.) Specify the Unicode character to apply to desired remap function.[Start Activity] Intent (Remap type must be Unicode for this value to have an effect.) Specify the package name for desired activity to launch.

 

 

Network Setting

 OEMConfig SettingsDescriptionEnable airplane modeEnables airplane mode on the device. Disabled by default.
Note: A manual reboot is required for changes take effect.EnableEnables the Bluetooth radio. Enabled by default.Device nameSet the friendly name of the device to be seen by other devices when discoverable during Bluetooth scan.Ethernet enable (Memor 20 only)Check this to enable the ethernet connection capability on Memor 20 devices. Default value is false. Note that the device has to be manually rebooted for this to work.Enable mobile dataEnables mobile data for internet access on cellular enabled devices. Enabled by default.Enable mobile data roamingEnable mobile data connection when roaming. Disabled by default. Delete all APN entriesRemove all currently configured APN entries. Disabled by default.
Note: Deletion will occur before adding new entries.Delete APN entriesSpecify the list of APN names (separated by commas) to delete. 

 

 

APN

 OEMConfig SettingsDescriptionEntry nameName the APN entry.Preferred APNSet the APN entry as the preferred APN. Disabled by default.APNName of the access point network.ProxySpecify the proxy address.PortSpecify the port number.UsernameSpecify the APN username. PasswordSpecify the APN password.ServerSpecify the APN server address. MMSCSpecify the APN MMSC URL.MMS proxySpecify the APN MMS proxy address.MMS portSpecify the APN MMS proxy port number.Authentication typeSecurity protocol used to send username and password to the server to establish a network connection. The available values are PAP, CHAP, PAP or CHAP.APN typeSpecify the APN types separated by commas. APN protocolSelect the APN connection protocol. The default value is IPv4.Roaming ProtocolSelect the protocol to connect to this APN when roaming. The default value is IPv4. 

 

 

NFC and Wi-Fi

 OEMConfig SettingsDescriptionNFC adapter enableCheck to enable the NFC adapter. This allows data to be exchanged between the devices when one touches the other. Enabled by default.Enable open network notificationIf enabled, the device will show open network notifications when it is in the vicinity of an open network and is not connected to the internet. Enabled by default.Sleep policyConfigure when the Wi-Fi should go to sleep on the device. When Wi-Fi is off, device will use mobile data as the primary mechanism to connect to the internet. The available options are Never (default), Never While Plugged, and Default.Scan intervalSet the time interval in seconds between two consecutive scans executed when device is in “on” and “wi-fi disconnected” condition. The valid value ranges between 2 and 300, by default this is 5. Remember to reboot the device after policy association for the changes to take effect.Scan interval maxSet the maximum time interval between scans (in seconds) when the device is on and disconnected. The valid value ranges between 2 and 300, by default this is 10. Remember to reboot the device after policy association for the changes to take effect.Connected scan intervalSet the time interval between scans (in seconds) when the device is on and connected. The valid value ranges between 2 and 300, by default this is 20. Remember to reboot the device after policy association for the changes to take effect.Connected scan interval maxSet the maximum time interval between scans (in seconds) when the device is on and connected. The valid value ranges between 2 and 300, by default this is 160. Remember to reboot the device after policy association for the changes to take effect.802.11 modeChoose the Wi-Fi 802.11 mode to use on the device. Changes will only be available on the device after a reboot. The default value is All enabled.Band selectionChoose the Wi-Fi band to be used on the device. Changes will only be available on the device after a reboot. The default value is All enabled.Power saveChoose the Wi-Fi power save mode. Changes will only be available on the device after a reboot. The default value is All enabled.Verbose Wi-Fi module loggingToggle on to enable the verbose Wi-Fi module logging for the device. Changes will only be active on the device after a reboot. The default value is All enabled.Roaming RSSI threshold (db)Enter a value of the signal threshold for triggering the roaming procedure. When the access point signal enters the threshold value, the device will scan for suitable networks to roam in the background. Choose a value between 10 and 120. Changes will not be active until the device is rebooted. By default, this is 76.Roaming RSSI difference (db)Enter the difference in signal between the presently connected access point and the target access point to which the device wants to roam to. If the target signal is higher than the current by at least this value, the device will roam. Choose a value between 0 and 30 (default is 5). NOTE: changes will not be active only after a reboot.

 

 

System Settings

 OEMConfig SettingsDescriptionEnable auto timeAutomatically fetch both time and date from the network. Enabled by default.Enable auto time zone [cellular only]Automatically fetch both time and date from the cellular network. Disabled by default.Select time zoneSelect the time zone.
Note: If device is connected to a cellular network and auto time zone is enabled, this setting will be overwritten.Enable 24-hour formatSet clock in 24-hour format.NTP serverSpecify the server address to use for NTP time syncing.Screen brightnessSets the screen backlight brightness. Default value is 70.Adaptive brightnessEnables the automatic optimization of brightness level for available light. Disabled by default.Auto-rotateEnable automatic rotation of device screen. Disabled by default.Font sizeSet the font size.Disable touch screenToggle on this option to prevent users from using the touch screen features to interact with the device. Note that only the hardware buttons remain operable for the user to control the device. By default this is false.2nd display enableEnable to allow the 2nd display feature on a Memor 20. This option is disallowed by default.Add packagesEnable 2nd display notifications for the package names that you have specified. Separate the package names with commas.Remove packagesEnter the package names (separated by commas) for which you have to disable 2nd display notifications.BrightnessSet the brightness of the 2nd display. The default value is 100.SleepSet the sleep timeout for the 2nd display. By default, this is Never timeout.Rotation enableIf toggled on the text can be rotated by 180 degrees.Rotation speedSpecify the rotation speed of the 2nd display. The available values are Slow (default), Medium and Fast.Enable new app notificationsEnable to enable notifications for all apps on the 2nd screen. Default value is true.Select LocaleSelect the locale to apply to the device.Location mode Used to enable/disable location services. Default value is GPS on.Sound SourceSelect the sound category to adjust. Volume LevelSet the volume level for the selected sound source. Default value is 50.Enable dial pad tonesEnables the dial pad tones when dialing. Enabled by default. Enable charging soundsEnable sounds during charging events. Enabled by default.Enable touch soundsEnable sound effects on touching the device screen. Enabled by default.Enable touch vibration (haptic)Enable haptic feedback. Enabled by default. Enable USB debuggingEnables the Android Debug Bridge (ADB) over USB. Disabled by default.

 

 

Firmware Update

 OEMConfig SettingsDescriptionReset TypeSelect the type of reset to perform after a firmware update completes. Default value is None.OTA Update FileSpecify the complete path to the file on the device that is to be used for a firmware update.

 

 

21. Click **Done** after selecting the required configurations.
22. Associate the policy with the target devices by navigating to the **Policy Targets** tab.
23. Select the required **Devices/Device Groups/Users/User Groups/Domains** to which the policy is to be associated.
24. Click on **Save**.

 Note: The OEM specific-settings explained in this document are based on the configurations set by the respective OEM vendors, which may vary frequently. Since Hexnode is not solely responsible for setting up these configurations, you may find slight variations in the settings displayed on the portal from this document.